FT/FIT-1001 Overview
FT & FIT-1001 Series are analog two wire flow transducers with a square root extractor, scaling multiplier, and output filter complete in a single package. The 4-20 mA output of the transducers is linear to velocity or volume. Each transducer is factory spanned and calibrated to meet the design requirement of the application and flow measuring elements being served. Optional features include local indication of the measured process air velocity and/or volume on either a 0.5 inch high 3-1/2 digit LCD display meter scaled in cfm (Model FIT-1001-D) and a built-in three-way manual zeroing valve for ease of zero verification and calibration (Models FT-1001-ZV, FIT-1001-DZV).
| Specifications | FT-1001 | FIT-1001-D |
|---|---|---|
| Accuracy | ±1.00% Full Scale ±0.5% Full Scale (Optional) | ±1.00% Full Scale ±0.5% Full Scale (Optional) |
| Display | None | LCD |
| Enclosure | FR110 Polycarbonate | Flame retardant ABS plastic |
| Supply Power | 12-36 VDC | 18-36 VDC |
| Output | 4-20mA (2 Wire) | 4-20mA (2 Wire) |
| Temperature Limits | Operating 32°F-140°F Storage -40°F-160°F | Operating 32°F-140°F Storage -40°F-160°F |
| Zeroing Valve | None (Standard) Manual Zeroing Valve (Optional) | None (Standard) Manual Zeroing Valve (Optional) |
FT/FIT-1003 Overview
FT & FIT-1003 Series are analog three wire flow transducers with a square root extractor, scaling multiplier, and output filter complete in a single package. The 0-5 or 0-10 VDC output of the transducers is linear to velocity or volume. Each transducer is factory spanned and calibrated to meet the design requirement of the application and flow measuring elements being served. Optional features include local indication of the measured process air velocity and/or volume on either a 0.5 inch high 3-1/2 digit LCD display meter scaled in cfm (Model FIT-1003-D) and a built-in three-way manual zeroing valve for ease of zero verification and calibration (Models FT-1003-ZV, FIT-1003-DZV).
| Specifications | FT-1003 | FIT-1003-D |
|---|---|---|
| Accuracy | ±1.00% Full Scale ±0.5% Full Scale (Optional) | ±1.00% Full Scale ±0.5% Full Scale |
| Display | None (Standard) | LCD |
| Enclosure | FR110 Polycarbonate | Flame Retardant ABS Plastic |
| Supply Power | 12-36 VDC | 18-36 VDC |
| Output | 0-5 VDC (Standard) 0-10 VDC (Optional) | 0-5 VDC (Standard) 0-10 VDC (Optional) |
| Temperature Limits | Operating 32°F-140°F Storage -40°F-160°F | Operating 32°F-140°F Storage -40°F-160°F |
| Zeroing Valve | None (Standard) Manual Zeroing Valve (Optional) | None (Standard) Manual Zeroing Valve (Optional) |
FT/FIT-1005 Overview
FT & FIT-1005 Series are analog four wire flow transducers with a square root extractor, scaling multiplier, and output filter complete in a single package. The 4-20 mA, 0-5 VDC, or 0-10 VDC selectable output of the transducers is linear to velocity or volume. Each transducer is factory spanned and calibrated to meet the design requirement of the application and flow measuring elements being served.
| Specifications | FT-1005 |
|---|---|
| Accuracy | ±0.50% Full Scale ±0.25% Full Scale (Optional) |
| Display | None |
| Enclosure | NEMA 12, Steel NEMA 4, Steel (Optional) |
| Supply Power | 18-28 VDC |
| Output | 4-20mA or 0-10 VDC 0-5v (Optional) |
| Temperature Limits | Operating 32°F-160°F Storage -40°F-180°F |
- Technical Data Sheets
- Technical Data Sheets

FT1000 Series
Air Volume/Velocity Transducers
- Technical Data Sheets
- Technical Data Sheets
The FT-1000 Series are cost-effective, accurate, and plug-n-play analog flow transducers ideal for applications that don’t require network communication or microprocessor technology. A wide array of options for power, output, display and enclosure type make them suitable for most applications.